Description:
The SIT 440 D3 is a compact, manual gas safety control valve featuring a thermoelectric flame failure device and an adjustable pilot outlet. It’s designed for heaters, ovens, barbecues, and commercial kitchen appliances that require reliable flame supervision and compliant gas control.
Key Features
- Thermoelectric safety shutdown (flame failure device) to interrupt gas flow if the pilot flame is lost.
- Pilot outlet with flow adjustment screw for precise pilot flame control.
- Thermocouple connection: M9×1; pilot connection options: Ø 6 mm or Ø 4 mm / M10×1.
- Optional M18×1 thread beneath push‑button.
- Suitable for any mounting position; compact dimensions for tight installs.
Technical Specifications
- Inlet/Outlet Connections: Rp 1/2″ (ISO 7) standard; Rp 3/4″ available on request.
- Maximum Inlet Pressure: 50 mbar.
- Ambient Temperature Range: 0–80 °C.
- Thermocouple: M9×1; Pilot connection: Ø 6 mm or Ø 4 mm / M10×1.
-
Flow Rates (Δp = 5 mbar):
- ½″: Family I 10.7 m³/h; Family II 10.0 m³/h; Family III 5.8 kg/h.
- ¾″: Family I 13.1 m³/h; Family II 12.2 m³/h; Family III 7.1 kg/h.
- Dimensions: Approx. 77 mm length × 38.5 mm body width.
- Weight: ~0.393 kg.
- Standards/Compliance: EN 125 (Flame supervision devices for gas‑burning appliances).
Typical Applications
- Commercial and domestic gas appliances requiring flame supervision: heaters, ovens, barbecues, and commercial deep fryers.
Original: $289.33
-65%$289.33
$101.27Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Description:
The SIT 440 D3 is a compact, manual gas safety control valve featuring a thermoelectric flame failure device and an adjustable pilot outlet. It’s designed for heaters, ovens, barbecues, and commercial kitchen appliances that require reliable flame supervision and compliant gas control.
Key Features
- Thermoelectric safety shutdown (flame failure device) to interrupt gas flow if the pilot flame is lost.
- Pilot outlet with flow adjustment screw for precise pilot flame control.
- Thermocouple connection: M9×1; pilot connection options: Ø 6 mm or Ø 4 mm / M10×1.
- Optional M18×1 thread beneath push‑button.
- Suitable for any mounting position; compact dimensions for tight installs.
Technical Specifications
- Inlet/Outlet Connections: Rp 1/2″ (ISO 7) standard; Rp 3/4″ available on request.
- Maximum Inlet Pressure: 50 mbar.
- Ambient Temperature Range: 0–80 °C.
- Thermocouple: M9×1; Pilot connection: Ø 6 mm or Ø 4 mm / M10×1.
-
Flow Rates (Δp = 5 mbar):
- ½″: Family I 10.7 m³/h; Family II 10.0 m³/h; Family III 5.8 kg/h.
- ¾″: Family I 13.1 m³/h; Family II 12.2 m³/h; Family III 7.1 kg/h.
- Dimensions: Approx. 77 mm length × 38.5 mm body width.
- Weight: ~0.393 kg.
- Standards/Compliance: EN 125 (Flame supervision devices for gas‑burning appliances).